A pilot light that won't stay lit is a specific, well-understood problem with a handful of usual causes and one clear safety boundary.
Tell us what you need—we’ll call you back fast.
Quick answer
A pilot that keeps going out is most often a worn thermocouple failing to hold the gas valve open, a draft blowing the flame out, or a partly blocked pilot orifice. Relighting a pilot yourself is generally fine if your furnace has clear instructions posted on it, but if it won't hold a flame after a couple of tries, stop and call a technician rather than repeating the process.
Need a licensed gas fitter for your gas furnace? Call CANRO at (604) 359-1081 — residential natural-gas heating and hot water across Metro Vancouver since 1999.
Older furnaces, more common in Fraserview's original post-war bungalows than in newer River District construction, often use a standing pilot light with a thermocouple rather than the electronic hot-surface igniter found in newer units. That older design is simple and reliable for years, but the pilot assembly is also the part most likely to develop a fault as the furnace ages, since it's a small mechanical component sitting directly in the flame.
If your furnace has an electronic igniter instead of a standing pilot, a "pilot won't stay lit" symptom usually means something different — most likely a flame sensor issue — so it's worth confirming which type your furnace actually has before troubleshooting.
Replacing a thermocouple, cleaning or replacing a pilot orifice, or diagnosing a gas valve that won't hold requires opening the gas-fired section of the furnace, which is licensed work under Technical Safety BC. A thermocouple in particular is a cheap, quick fix for a technician but fiddly to diagnose correctly without the right test equipment, since a marginal thermocouple can sometimes hold a flame just long enough to seem fixed before failing again the next cycle.
If you've relit the pilot two or three times and it keeps going out, that's the point to stop and book a visit rather than keep repeating the process, both for safety and because repeated relighting wastes gas without fixing the underlying cause.
The technician checks the thermocouple's millivolt output against the gas valve's requirements, inspects the pilot orifice and flame quality, and rules out drafts or venting issues in the mechanical space. A worn thermocouple is typically replaced on the spot, and the pilot is tested through several full cycles before the visit wraps up to confirm it's holding reliably, not just working once.
If the furnace is old enough that the whole standing-pilot assembly is becoming unreliable and parts are getting harder to source, the technician will discuss what replacement with a newer furnace would look like, generally $4,500 to $9,500+ as a ballpark, not a quote, once they've assessed your specific setup.
Safety note
If you smell gas while trying to light or relight a pilot, stop immediately, leave the gas control knob off, get everyone out of the home, and call FortisBC's emergency line at 1-800-663-9911 from outside. Gas valve, thermocouple, and pilot assembly repairs must be done by a Technical Safety BC licensed gas fitter.
Following the printed instructions once or twice is reasonable. If it won't hold after that, stop trying and call for service rather than repeating the process, since it likely means a part needs replacing.
It's one of the more affordable furnace repairs, and it's a quick job for a licensed technician once diagnosed, though exact pricing depends on the part and access, and the office confirms that after a short assessment.
A draft reaching the pilot assembly, sometimes through a venting gap or a door left open near the furnace, can blow a standing pilot out on its own even with a healthy thermocouple, so wind-correlated outages point a technician toward checking the draft path.
Most newer furnaces use an electronic hot-surface igniter instead of a standing pilot, so if your Fraserview home has a newer furnace and you're seeing ignition trouble, it's more likely a flame sensor or igniter issue than a classic pilot problem.
You can, but going without heat isn't necessary for most pilot issues — a thermocouple replacement is usually quick, so it's worth booking a visit rather than living without heat for an extended stretch.
Family-run, TSBC-licensed (gas LGA0043870 · boiler LBP0046450), serving Metro Vancouver homes since 1999. Residential, natural gas only.
Call (604) 359-1081 Email info@canroheat.ca“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.