Every gas furnace goes through the same handful of steps to start, and a furnace that won't ignite has simply stalled at one specific one of them.
Tell us what you need—we’ll call you back fast.
Quick answer
A furnace that won't ignite has stalled somewhere in its start-up sequence — the thermostat calls for heat, the inducer motor purges the combustion chamber, the igniter fires, and a flame sensor confirms the flame before the main blower runs. What you hear tells you roughly where it stalled: total silence points to power, a motor running with nothing after it points to venting, and clicking with no sustained flame points to the igniter, gas valve, or flame sensor. A licensed technician can pin down exactly which.
Need a licensed gas fitter for your gas furnace? Call CANRO at (604) 359-1081 — residential natural-gas heating and hot water across Metro Vancouver since 1999.
A modern gas furnace doesn't just 'turn on' — it runs through a fixed sequence every single cycle: the thermostat signals a call for heat, the inducer motor spins up to clear the combustion chamber and confirm venting is unobstructed, the igniter heats or sparks, gas is released, and a flame sensor has to detect the resulting flame before the system allows the main blower to run. Knowing this sequence exists is genuinely useful, because where the furnace stalls narrows the cause significantly before a technician even opens the panel.
| What you notice | Where it's likely stalling |
|---|---|
| Complete silence, nothing at all | Power supply, thermostat, or the furnace's own switch |
| Inducer motor runs, then the sequence stops | Pressure switch not confirming clear venting |
| Repeated clicking, never any flame | Igniter not heating properly, or the gas valve isn't opening |
| A flame appears briefly, then cuts out | Flame sensor not registering it, shutting gas flow as a safety response |
The igniter, flame sensor, gas valve, and pressure switch all sit behind the furnace's own safety design and involve live gas or precisely rated electrical components — testing them properly means using the right meters in the right sequence, not something to improvise. If your furnace consistently stalls at the same point each attempt, tell the technician that pattern directly; it's genuinely useful diagnostic information and usually points toward one specific failed component.
Homes in Fraserview closer to the Fraser River and the dike can see somewhat higher humidity around exterior vent terminations during the wetter months, and in colder snaps that moisture is occasionally enough to contribute to minor ice buildup right at the vent opening. Because the pressure switch has to confirm the vent is genuinely clear before the igniter is allowed to engage at all, even a partial obstruction there can stop the sequence before it produces any clicking or spark sound.
A single failed igniter or flame sensor is usually a contained, straightforward repair, and the office confirms the price once a technician has identified the specific part involved. If the furnace has had multiple unrelated failures recently, or parts are proving hard to source for an older model, replacement is worth discussing — generally $4,500 to $9,500+ as a ballpark, confirmed by CANRO after assessing your home, not a number quoted without seeing it.
Safety note
Igniters, flame sensors, gas valves, and pressure switches must be diagnosed and repaired by a Technical Safety BC licensed gas fitter — CANRO holds gas licence LGA0043870. If you smell gas at any point, leave the home immediately and call FortisBC's emergency line from outside, 1-800-663-9911.
Repeated clicking with no sustained flame usually points to the igniter not heating enough to light the gas, or the gas valve not opening properly on cue — both need a technician to test and replace as needed.
It can contribute — higher humidity around an exterior vent termination in colder snaps can occasionally lead to minor blockage that a pressure switch detects, stopping ignition before it starts.
Trying the thermostat and furnace switch once or twice is fine, but if it consistently stalls at the same step, repeated attempts don't fix the cause — book a technician instead.
Complete silence with no sound at all usually points to power; a motor running, or clicking, followed by no flame points to somewhere further along the ignition sequence.
A quick visual check for obvious debris, a nest, or snow at the termination is reasonable; anything beyond that, including confirming the pressure switch itself, needs a technician.
If the furnace has had several unrelated failures recently or parts are becoming difficult to source for an older model, replacement is worth comparing against another repair, and CANRO can walk through both after inspecting the unit.
Family-run, TSBC-licensed (gas LGA0043870 · boiler LBP0046450), serving Metro Vancouver homes since 1999. Residential, natural gas only.
Call (604) 359-1081 Email info@canroheat.ca“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.