When a John Wood gas water heater in Tsawwassen stops producing hot water, the cause is usually a pilot or ignition fault, a failed thermocouple, or sediment build-up rather than a full tank failure.
Tell us what you need—we’ll call you back fast.
Quick answer
No hot water from a John Wood gas tank in Tsawwassen most often comes down to a pilot light or igniter that's gone out, a failing thermocouple or flame sensor, a stuck gas control valve, or heavy sediment insulating the burner from the water. Coastal wind through crawlspace vents is a locally common trigger for pilot outages on older standing-pilot models here, so that's usually the first thing worth checking before assuming a bigger fault.
Need a licensed gas fitter for your tank water heater? Call CANRO at (604) 359-1081 — residential natural-gas heating and hot water across Metro Vancouver since 1999.
The first useful distinction is whether the water is stone cold or just noticeably cooler than it should be. Completely cold water at every tap points toward the burner not firing at all, usually a pilot outage, a failed igniter on a power-vent model, or a gas control valve that's stopped opening. Lukewarm water that never reaches proper hot usually points to something less dramatic: a mixing or recirculation issue, a dip tube failure letting cold incoming water mix with the hot supply near the top of the tank, or a burner that's firing but underperforming due to heavy sediment.
Knowing which situation you're in before a technician arrives helps narrow the visit down faster, and it's worth checking both a bathroom tap and the kitchen to see if the temperature issue is consistent across the house or isolated to one fixture, which can point toward a plumbing issue rather than the tank itself.
A number of older Tsawwassen homes have their John Wood tank in a crawlspace with vents to the outside for combustion air, and those vents are directly exposed to the wind that comes off Boundary Bay, especially during fall and winter storms. A strong enough gust through a poorly sealed crawlspace can occasionally snuff a standing pilot light on an older atmospheric-vent tank, which produces a sudden, complete loss of hot water with no other symptoms. Relighting the pilot following the instructions on the tank's label sometimes resolves it on the spot, but if it keeps going out repeatedly, that's a sign of either a genuine draft problem in the crawlspace or a weakening thermocouple that's no longer holding the gas valve open reliably.
| What you're noticing | Likely cause |
|---|---|
| Pilot light is out, won't stay lit | Draft in the crawlspace, or a failing thermocouple |
| Power-vent model, no ignition sound at all | Igniter, control board, or blower fault |
| Water lukewarm but never hot | Sediment buildup, or a failing dip tube |
| Hot water runs out fast then goes cold | Undersized recovery for current demand, or heavy sediment |
| Rumbling sound, then reduced output | Sediment layer interfering with burner heat transfer |
A proper diagnostic visit starts with confirming gas supply and pilot or ignition status, then moves to testing the thermocouple or flame sensor's actual output rather than just visually inspecting it, since a thermocouple can look fine but still be failing electrically. If the burner lights but the water still isn't heating properly, the technician checks for sediment by draining a sample from the bottom of the tank and reviewing how much resistance the flush shows. On power-vent models, the blower, igniter, and control board each get checked individually since a fault in any one of them can produce the same symptom of no ignition.
This is genuinely a case where guessing at parts wastes money. A thermocouple swap won't fix a control board fault, and vice versa, so proper diagnosis before any repair matters.
If the tank is well past a typical service life, has needed repeated pilot or ignition repairs over the past year or two, or shows visible corrosion at the base alongside the no-heat symptom, a repair-only approach starts to make less financial sense. This is particularly relevant for older crawlspace tanks in this area that have been dealing with both age and coastal air exposure simultaneously. A technician can walk through what's repairable versus what's a sign the tank's overall condition, not just this one fault, is the real issue.
Safety note
Diagnosing and repairing a gas water heater's ignition, pilot, or control components must be done by a Technical Safety BC licensed gas fitter. If you smell gas at any point while checking the tank, leave the home immediately and call FortisBC's emergency line at 1-800-663-9911 from outside.
In older Tsawwassen crawlspace installs, wind coming through combustion air vents can occasionally snuff a standing pilot. If it's a one-off during a storm, relighting it may solve it, but repeated outages point to a draft problem or a weakening thermocouple worth having checked.
Following the manufacturer's label instructions to relight a pilot is generally something a homeowner can do, but if it won't stay lit or keeps recurring, that's a sign of an underlying issue that needs a licensed gas fitter to diagnose properly.
No, a completely out pilot usually means stone-cold water. Lukewarm water more often points to sediment buildup, a failing dip tube, or a burner that's firing but underperforming, which is a different diagnosis path.
Both can produce similar symptoms, which is exactly why a proper diagnostic test of the thermocouple's actual electrical output, rather than a visual check alone, is needed before replacing either part.
Power-vent models use a sealed combustion system with an electric igniter rather than a standing pilot exposed to the surrounding air, so they're generally less affected by crawlspace drafts, though blower or igniter faults can still cause a no-heat symptom.
Yes, repeated no-hot-water calls on the same tank, especially an older one, is worth a full assessment rather than another one-off repair, since it may be a sign the tank's overall condition is declining.
Family-run, TSBC-licensed (gas LGA0043870 · boiler LBP0046450), serving Metro Vancouver homes since 1999. Residential, natural gas only.
Call (604) 359-1081 Email info@canroheat.ca“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.