The T-H3 is a full-size condensing unit; the T-KJr2 is a compact non-condensing model built for tight mechanical spaces and lighter hot-water demand.
Tell us what you need—we’ll call you back fast.
Quick answer
The Takagi T-H3 is a condensing tankless water heater sized for whole-home duty, while the T-KJr2 is a compact non-condensing unit built to fit into tighter mechanical spaces where demand is lighter. The T-H3's extra internal heat exchanger means plastic venting and a condensate drain; the T-KJr2's simpler non-condensing design vents with stainless steel and needs no condensate line at all, which sometimes makes it the more practical retrofit in a cramped utility closet. The right choice comes down to how much simultaneous hot water your household actually needs and how much room the mechanical space gives you to work with.
Need a licensed gas fitter for your tankless water heater? Call CANRO at (604) 359-1081 — residential natural-gas heating and hot water across Metro Vancouver since 1999.
The T-H3 and the T-KJr2 sit at different points in Takagi's tankless lineup, and the gap between them is bigger than just physical size. The T-H3 is a condensing unit — it uses a second heat exchanger to reclaim heat from the exhaust before venting outside, and that design is built for homes running multiple fixtures at once. The T-KJr2 is a compact non-condensing unit, built with a smaller footprint in mind for homes or additions where floor space or wall space in the mechanical room is genuinely tight.
We see the T-KJr2 come up most often in laneway homes, garden suites, and older houses where the original mechanical closet was never designed around a full-size appliance. The T-H3 shows up more in main-house installs where the household is running a shower, a dishwasher, and laundry on the same morning.
Because the T-H3 condenses, it typically vents with PVC or CPVC pipe and needs a condensate drain routed to a floor drain, laundry standpipe, or small pump. The T-KJr2, being non-condensing, vents with stainless steel rated for its higher exhaust temperature and skips the condensate question entirely — there's no acidic liquid to route anywhere. In a small suite where there's no floor drain within reach, that alone can settle the decision in the T-KJr2's favour.
The trade-off is that stainless steel venting has its own length and clearance rules, and in a compact space those clearances to combustibles, windows, and soffit vents still have to be checked against the manufacturer's venting tables and the BC Building Code before anything gets installed.
| Feature | T-H3 (condensing) | T-KJr2 (compact non-condensing) |
|---|---|---|
| Combustion type | Condensing | Non-condensing |
| Venting material | Plastic (PVC/CPVC) | Stainless steel |
| Condensate drain | Required | Not required |
| Typical placement | Main-house mechanical room | Suites, laneway homes, tight closets |
A good share of the smaller-unit calls we get are tied to laneway houses and basement suites built to add hot-water demand onto a lot that already had one water heater serving the main house. Squeezing a full condensing unit and its condensate line into a laneway home's tiny mechanical closet is sometimes possible, but a compact non-condensing unit avoids the drain question altogether and can be easier to mount in a shallow closet or over a stacked washer-dryer.
On the main house side, we more often steer toward the condensing T-H3 platform because a family running two bathrooms and a kitchen at the same time benefits from the steadier output a full-size condensing unit is designed to hold under that kind of simultaneous draw.
We measure the mechanical space, count fixtures and how many typically run together, and check whether a condensate drain point exists before recommending either platform. If the space and the demand both point the same direction, the decision is simple; if they pull in opposite directions — tight space but heavy demand — we'll walk you through the real trade-offs rather than force a fit. Installation pricing for either unit is a 2026 public-market ballpark, not a firm quote, and gets confirmed by CANRO's certified technicians once they've seen the space in person.
Safety note
If you smell gas anywhere near a water heater, notice a yellow or flickering flame, or soot around the unit, get everyone out of the house first and call FortisBC's emergency line at 1-800-663-9911 before doing anything else. Both units must be installed and vented by a Technical Safety BC licensed gas fitter; CANRO holds gas licence LGA0043870.
It's built for lighter or more limited demand than a full-size condensing unit, so whether it can carry a whole house depends on how many fixtures run at once — we size it against your actual usage rather than assume.
Not really. Both platforms still need periodic descaling based on your water hardness; the compact unit just avoids the condensate line that a condensing unit needs cleaned and checked.
It often is, especially where the mechanical closet is shallow or there's no floor drain nearby for a condensate line, though we still confirm venting clearances before recommending it.
If the household runs multiple fixtures at once — a shower, laundry, and a dishwasher together — the full-size condensing platform is generally built to hold output more comfortably under that kind of simultaneous draw.
Yes. Even a compact unit can draw more gas instantaneously than an old tank, so we verify line sizing and meter capacity regardless of which series goes in.
Yes, gas work and venting for a suite or laneway home require a permit like any other installation, and CANRO handles that as part of the job.
Family-run, TSBC-licensed (gas LGA0043870 · boiler LBP0046450), serving Metro Vancouver homes since 1999. Residential, natural gas only.
Call (604) 359-1081 Email info@canroheat.ca“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.