Photograph the complete message and the indoor unit model label if it is visible without removing a cover. Keep the outdoor model and controller model with that record. A ceiling cassette, concealed ducted unit and wall-mounted unit can have different condensate arrangements, even when they share the same brand.
Mitsubishi Electric documentation identifies P5 as drain overflow protection for specific equipment families. That is useful starting information, not a universal diagnosis for every Mitsubishi product. Mitsubishi Electric and Mitsubishi Heavy Industries are separate manufacturers; a code table for one should not be used to order parts for the other.
During cooling, moisture removed from indoor air collects at the indoor coil and needs a clear drainage route. Depending on the installation, water leaves by gravity or through a condensate pump. A drainage protection signal is a reason to stop and investigate before water reaches a ceiling, wall or nearby electrical equipment.
Mitsubishi’s PEA-M LA2 service manual lists drainage, pump, float-switch and controller checks for P5. Those checks belong to the service technician. They are not instructions to bridge a float switch or open a live indoor unit.
Keep clear of wet electrical equipment. Do not remove covers, probe wiring, bypass a float switch, force water or chemicals into the unit, or repeatedly reset a tripping breaker. Stop using equipment that is leaking or behaving abnormally and arrange qualified HVAC service.
Send CANRO the model number, code photo and your Greater Vancouver location. We can confirm service availability and the next diagnostic step.
📞 (604) 359-1081Request a quoteAsk for the cause of the protection event, not just a replacement-part recommendation. The assessment should explain whether water is actually backing up, whether drainage meets the model’s installation requirements, and whether the pump and sensing circuit work as intended. Any electrical testing should follow the manufacturer’s procedure.
After repairs, ask what operating test was completed to confirm drainage. A disappearing display is not the same as proving that water can leave the unit during use. If access requires a ceiling panel, discuss access and any making-good work before the appointment.
A condensate fault is not an automatic reason to replace the entire heat pump. Compare the diagnosed problem, available parts, repair scope and the overall condition of the equipment. Ask whether the quote includes drain cleaning, pump replacement if needed, access work and a drainage test. A generic P5 price online cannot account for those differences.
For wider system decisions, see our repair-or-replace guide. For another displayed code, use the HVAC error-code guide and verify the exact equipment manual.
Sources checked 2026-09-17. Equipment manuals and program terms can change. Use the documentation for your exact model or application.
“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.