When an NCB-H combi stops heating the house, the first question is whether hot water still works, and the answer splits the causes cleanly in two.
Tell us what you need—we’ll call you back fast.
Quick answer
If a Navien NCB-H combi boiler is not heating, first check whether domestic hot water still works, because that tells you whether the boiler can fire at all. If hot water works but the radiators or floors stay cold, look at the thermostat and its settings, the system pressure on the gauge and whether the circulator is running. If nothing works, look at the display, the power supply to the boiler and whether a lockout has occurred, and call a licensed gas fitter rather than resetting repeatedly or opening the boiler.
Need a licensed gas fitter for your gas boiler? Call CANRO at (604) 359-1081 — residential natural-gas heating and hot water across Metro Vancouver since 1999.
A combi boiler does two things with one burner: it heats the house and it makes hot water. Most no-heat calls start with a shivering household, and the first question we ask on the phone is whether the shower still gets hot. If it does, the burner, gas supply, fan and ignition are probably working, and the problem sits in the heating call, the pump or the loop. If neither works, the boiler itself has stopped or locked out, and the cause is more likely gas, ignition, condensate, venting or power.
The Navien NCB-H is listed by the manufacturer as a condensing combi boiler. Condensing combis are sensitive to a handful of things that homeowners can safely look at, and to a longer list that only a licensed gas fitter should touch. This guide separates the two.
That is the end of the homeowner list. Opening the cabinet, adjusting gas valves, draining the system and pressing reset over and over are not safe or useful steps.
This pattern points away from the burner and toward the heating side. Possible causes, from the most to the least common in our experience: a thermostat or zone control that is not calling; low system pressure that has stopped the heating circuit; air in the loop or in the circulator; a circulator that has failed or seized; a zone valve that is stuck closed; a diverter or valve inside the boiler that is not switching properly; or a blockage in the loop from sludge.
A technician tests each in turn, starting with what the thermostat is asking for and ending with flow through the loop. Measuring temperatures along the supply and return pipes quickly shows whether hot water is leaving the boiler and where it stops.
This one is usually a domestic-side issue: a fouled plate heat exchanger, a blocked inlet strainer, a flow sensor or diverter that is not registering a tap opening, or a fault in the temperature sensing on the hot-water side. Because the heating side is working, the burner, gas and venting are typically fine. A technician tests flow and temperature at the boiler and at the fixtures.
A total shutdown suggests a safety lockout or a loss of power. Ignition faults, weak flame sensing, a blocked condensate path, a restricted vent and a gas supply issue can all cause it. In cold weather a frozen condensate line is a leading suspect. Because several of these involve combustion, the safe course is to leave the boiler off after one reasonable attempt and call. Repeated resets stress the components and, in the case of ignition faults, are not advisable.
| What you see | Likely areas | Who handles it |
|---|---|---|
| No display | Power, switch, breaker, control | Owner checks breaker once, then technician |
| Display on, no heat, hot water fine | Thermostat, zone, pump, pressure, air | Owner checks settings, technician does the rest |
| Display on, no hot water, heat fine | Flow sensor, diverter, plate exchanger, strainer | Technician |
| Lockout message | Ignition, flame, condensate, vent, gas | Technician, do not reset repeatedly |
| Gauge far below normal | Leak, air release | Technician, avoid refilling |
| Stopped in a cold snap | Frozen condensate line | Technician |
We work from the outside in. First the gas and power to the boiler, then the thermostat and controls, then what the display reports, then the physical path the boiler needs: venting, condensate and water. We watch a start-up sequence to see where it stops. Only then do we open the boiler to inspect the burner, ignition components and heat exchanger. We test each mode separately, since a combi's heating and hot-water paths share components but not all of them.
If the boiler needs a part, we quote it in writing before replacing it. If the problem points to something bigger, such as a compromised heat exchanger, we say so and discuss repair versus replacement, which we cover in a separate guide.
The wet, mild climate hides a cold-snap problem: frozen condensate lines. Older homes add sludge in cast-iron radiator loops. Renovations change things quietly, such as a valve closed by a plumber and never reopened, or a thermostat relocated to a spot that never calls. In the Fraser Valley, colder outflow winds and harder water add stress to the exterior components and the hot-water side. Basement mechanical rooms with a washer and dryer nearby can fill the boiler with lint, which affects combustion air.
A surprising share of no-heat calls end at the thermostat, the wiring to it or the zone control behind it. A thermostat relocated during a renovation, a smart thermostat that lost its network settings and reverted, a schedule accidentally set to away, or a battery that finally died can all leave the boiler quietly waiting for a call that never comes. In homes with multiple zones, one zone valve that fails closed can leave a single floor cold while everything else works. The boiler is fine; the call never arrives or the heat has nowhere to go.
We always ask what the thermostat display shows and whether it is asking for heat. If you can tell us that on the phone, the technician arrives with the right tools and often the right part. Please do not rewire a thermostat or change its settings extensively to test a theory. Set it to heat, set it a few degrees above the room temperature, and wait a few minutes before concluding anything.
The pattern of cold and warm rooms is a diagnostic map. If every room is cold, the boiler, the circulator or the pressure is the likely cause. If only the top floor is cold, air is high on the list. If only the rooms furthest from the boiler are cold, flow balance or a partly blocked loop is likely. If a single radiator is cold at the bottom and warm at the top, sludge has settled in it. Tell the technician which rooms are warm and which are not. It saves time, and it helps us bring the right parts and a flushing plan if one is needed.
CANRO Heating & Cooling has serviced boilers across Metro Vancouver since 1999, and every gas job is done by a Technical Safety BC licensed gas fitter.
Safety note
A combi boiler is a gas appliance with pressurised hot water. Do not open the boiler, adjust gas valves, drain or refill the system, or reset it repeatedly. If you smell gas, leave the home immediately without touching any switch and call FortisBC at 1-800-663-9911 from outside. If a carbon monoxide alarm sounds, get everyone out and call 911. Gas work must be done by a Technical Safety BC licensed gas fitter.
If hot water works, look at the thermostat, system pressure and circulator. If nothing works, look for a lockout, power problem, frozen condensate line or gas supply issue. A licensed gas fitter finds the exact cause.
At most one reset following your manual, and only if there is no smell of gas. If it locks out again, stop and call. Repeated resets stress the components and can hide a real fault.
The burner is probably working, so the cause is on the heating side: thermostat call, low pressure, air, a failed circulator, a stuck valve or sludge. A technician tests each in turn.
That points to the domestic side: a fouled heat exchanger, blocked strainer, flow sensor or diverter fault. Testing flow and temperature identifies which.
A frozen condensate drain is a common cause on condensing boilers. The technician thaws it, checks its slope and protects or reroutes it.
It can be, particularly with young children, seniors or health conditions. Tell us at the time of your call so we can plan accordingly, and keep warm with layers and closed interior doors while you wait.
Family-run, TSBC-licensed (gas LGA0043870 · boiler LBP0046450), serving Metro Vancouver homes since 1999. Residential, natural gas only.
Call (604) 359-1081 Email info@canroheat.ca“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.