A leaking boiler is rarely one single thing; the location of the water tells you far more than the fact that it is leaking at all.
Tell us what you need—we’ll call you back fast.
Quick answer
A Noritz boiler leak is most often coming from a loose or aging fitting, a relief valve discharging because of excess pressure, a failing internal seal or gasket, or a condensate drain problem on a condensing model. Where the water appears, and whether it is clear, mineral-stained, or slightly acidic condensate, points toward a different cause and a different urgency. A licensed technician traces the leak to its source rather than tightening the nearest fitting, since a leak elsewhere in the system can show up somewhere unrelated.
Need a licensed gas fitter for your gas boiler? Call CANRO at (604) 359-1081 — residential natural-gas heating and hot water across Metro Vancouver since 1999.
Water pooling under a boiler can come from the boiler's own internal components, from piping connections above or beside it, from the pressure relief valve doing exactly what it is designed to do, or from a condensate drain path if the unit is a condensing model. Two leaks that look identical on the floor can have entirely different causes and entirely different urgency, which is why tracing the source matters more than simply noting that water is present.
In older Vancouver-special homes with a boiler tucked into a converted basement, it is also common for a leak from an unrelated plumbing line or a nearby hose bib to be mistaken for a boiler fault, so confirming the water is actually coming from the heating system is a useful first step.
| What the water looks like | Likely source | What it suggests |
|---|---|---|
| Clear water at a fitting or joint | Loose connection or worn gasket | Usually a straightforward repair once located |
| Water discharging from a valve on top of or beside the boiler during or after heating | Pressure relief valve responding to high pressure | Points to an expansion tank or fill-valve problem upstream, not the valve itself |
| Water with a mineral crust or rust colour | Long-term slow leak at a fitting or an aging component | May indicate the leak has been present longer than realized |
| Water near a plastic hose with a faint sour smell | Condensate drain issue on a condensing unit | Different repair path than a pressure-side leak |
It is reasonable to place a container under an obvious drip and to note when the leak started and whether it changes with the boiler running versus idle. It is not a good idea to tighten fittings yourself, to keep adding water to compensate for a leak without knowing the cause, or to ignore a relief valve that is discharging, since that valve is a safety device responding to a real pressure problem rather than a nuisance to be worked around.
If the leak is significant enough that water is reaching electrical components or spreading toward the electrical panel, it is worth shutting off power to the mechanical room at the breaker, from a safe distance, and calling for service rather than waiting.
A licensed gas fitter will isolate the system, dry the area, and re-pressurize in stages while watching for where moisture reappears, which is a more reliable method than trying to spot a leak on a wet, already-dripping unit. Once the exact source is confirmed, the fix might be as simple as re-seating a fitting or as involved as replacing a heat exchanger gasket, and the technician can tell you which category you are in once the source is confirmed rather than before.
Safety note
Any diagnosis or repair on a gas-fired boiler must be carried out by a Technical Safety BC licensed gas fitter, since the combustion, venting, and control systems are all connected. If you ever smell gas, hear a hissing sound near a gas line, or notice soot or a burning odour near the unit, leave the home immediately and call FortisBC at 1-800-663-9911 from a safe location.
Not always, but a leak that is growing, reaching electrical components, or coming from the relief valve should be addressed promptly rather than monitored indefinitely.
That is almost certainly the pressure relief valve, and it discharges when system pressure exceeds its rated threshold. The underlying cause is usually upstream, such as an expansion tank or fill valve issue, rather than the valve itself being faulty.
It is best left to a licensed technician, since over-tightening a fitting on a pressurized gas appliance can cause more damage, and the true source of a leak is not always the fitting where water first appears.
Not necessarily. Many leaks are isolated to a single gasket or fitting and are repaired without replacing the unit. Replacement becomes relevant when leaks recur across multiple components or the boiler is otherwise near the end of its service life.
This pattern often points to a pressure-related cause, since pressure rises as the water heats, which can push a marginal fitting or seal past the point where it holds.
If the leak is minor and not near electrical components, it is fine to leave the unit running until a technician arrives, but shut off the water supply to the system if you know how, and always shut off power if water is reaching the electrical panel or controls.
Family-run, TSBC-licensed (gas LGA0043870 · boiler LBP0046450), serving Metro Vancouver homes since 1999. Residential, natural gas only.
Call (604) 359-1081 Email info@canroheat.ca“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.