The T&P valve is a tank's last line of defence against dangerous pressure buildup, and it needs to be confirmed working, not just assumed.
Tell us what you need—we’ll call you back fast.
Quick answer
The temperature and pressure relief valve, commonly called the T&P valve, is a safety device mounted on top of or near the side of a gas water heater tank that opens automatically to release water if internal temperature or pressure rises above a safe threshold, protecting against a dangerous pressure buildup. Testing involves briefly lifting the valve's test lever to confirm water discharges freely and then shuts off cleanly, which a licensed technician does as part of routine maintenance since a valve that has never been tested can seize in place and fail to open when actually needed. A valve that discharges on its own outside of a test, especially repeatedly, should be assessed rather than ignored.
Need a licensed gas fitter for your hot water / boiler? Call CANRO at (604) 359-1081 — residential natural-gas heating and hot water across Metro Vancouver since 1999.
A tank-style gas water heater holds a large volume of water at a set temperature under normal household pressure, and a malfunction that allows temperature or pressure to climb beyond safe limits could, in a worst case, be dangerous. The T&P valve is the tank's dedicated safety response to that risk: it is spring-loaded to stay closed under normal conditions but opens automatically to discharge water and relieve pressure if either temperature or pressure crosses its rated threshold, then closes again once conditions return to normal.
Because it exists specifically as a last line of defence, its reliability matters more than almost any other single component on the tank, which is exactly why it deserves a genuine periodic test rather than being assumed to work simply because it has never visibly discharged.
A discharge pipe that shows staining, mineral deposits, or a persistent drip at its end is worth mentioning at the next service visit, since it suggests the valve may not be sealing perfectly. If the valve discharges water on its own, outside of an intentional test, especially more than once, that is a sign of excess temperature or pressure in the system and should be reported promptly rather than treated as routine. Testing the valve yourself by lifting the lever is possible on some installations, but the water discharged is very hot and the valve can be difficult to reseat correctly afterward, so many homeowners prefer to have this done by a technician who can also inspect the valve and discharge pipe at the same time.
Never cap, plug, or otherwise block a T&P valve's discharge pipe, since doing so defeats the entire safety purpose of the valve and can create a genuinely dangerous condition.
| Finding | Typical outcome |
|---|---|
| Valve opens and reseats cleanly during test | No action needed, confirmed functioning |
| Valve fails to open during test | Valve replacement, not repaired in place |
| Valve drips continuously after test | Valve replacement, seat likely fouled or worn |
| Repeated unprompted discharge | Investigate system temperature and pressure cause, then reassess valve |
Safety note
Any work on the gas train, venting, or combustion side of a boiler or water heater must be done by a Technical Safety BC licensed gas fitter; CANRO holds gas licence LGA0043870 and boiler licence LBP0046450. If you ever smell gas, leave the home immediately and call FortisBC at 1-800-663-9911 before doing anything else.
It is a safety device that opens automatically to release water if the tank's internal temperature or pressure rises above a safe threshold, acting as a last line of defence against dangerous buildup.
It is generally tested as part of an annual maintenance visit, since a valve that has never been tested can seize in place and fail to open when actually needed.
A brief discharge during the test itself is expected, but a persistent drip afterward usually means the valve seat is fouled or worn and the valve should be replaced rather than left dripping.
No, never cap or block a T&P valve's discharge pipe; doing so defeats the valve's entire safety purpose and can create a dangerous condition.
An unprompted discharge, especially if it happens more than once, indicates excess temperature or pressure in the system and should be reported to a technician promptly rather than treated as routine.
It is possible on some installations by briefly lifting the test lever, but the discharged water is very hot and the valve can be tricky to reseat correctly, so many homeowners prefer to have a technician handle this along with a full inspection.
Family-run, TSBC-licensed (gas LGA0043870 · boiler LBP0046450), serving Metro Vancouver homes since 1999. Residential, natural gas only.
Call (604) 359-1081 Email info@canroheat.ca“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.