A plain-language explanation of how a gas water heater vents combustion exhaust, and how that differs between tank types common in Metro Vancouver.
Tell us what you need—we’ll call you back fast.
Quick answer
A gas storage water heater vents combustion exhaust either by natural draft through a single vertical metal flue, which is the older atmospheric design, or by a power vent or direct vent system that uses a fan to push exhaust out, often through sidewall PVC piping, which is more common on newer and higher-efficiency tanks. The right vent type and routing depend on the specific model, and swapping between types during a replacement usually means the venting has to be redesigned, not just reconnected.
Need a licensed gas fitter for your hot water / boiler? Call CANRO at (604) 359-1081 — residential natural-gas heating and hot water across Metro Vancouver since 1999.
A conventional atmospheric gas water heater relies on the natural buoyancy of hot exhaust gas rising through a vertical metal flue, typically connecting to a draft hood at the top of the tank and running up through the roof or into a shared chimney. This design has no fan and needs a reasonably straight, adequately sized vertical run to create enough natural draft to pull exhaust up and out. It also depends on the appliance drawing combustion air from the room it sits in, which is why atmospheric water heaters need adequate room volume or dedicated combustion air openings, a point that becomes important during basement renovations that enclose the mechanical space.
Atmospheric tanks are simple and have served Metro Vancouver homes for decades, but they are more sensitive to draft problems: a chimney that is oversized for the appliance now connected to it, competing exhaust from another appliance on a shared flue, or negative pressure created by strong kitchen or bathroom exhaust fans elsewhere in the house can all interfere with proper draft and lead to flue gas spillage.
A power-vented water heater uses a small fan to push exhaust out through PVC or similar pipe, usually terminating through a sidewall rather than the roof, and it still draws combustion air from the room like an atmospheric unit does. A direct-vent, sealed-combustion unit goes a step further, using two pipes, one for outdoor combustion air intake and one for exhaust, so it does not depend on room air at all. High-efficiency condensing tank water heaters typically use this sealed, direct-vent approach, similar in concept to tankless venting.
| Vent type | How it moves exhaust | Typical vent material |
|---|---|---|
| Atmospheric | Natural draft, hot air rises | Metal single-wall or B-vent, usually vertical |
| Power vent | Fan-assisted, room air for combustion | PVC or similar, often sidewall |
| Direct vent / sealed combustion | Fan-assisted, outdoor air for combustion | PVC/CPVC intake and exhaust pipe pair |
One of the most common venting mistakes we see is a straightforward-looking tank swap that turns into a bigger job because the replacement model uses a different vent type than the one it is replacing. Upgrading from an atmospheric tank to a higher-efficiency power-vent or direct-vent model means running new vent piping, often to a different termination point on an exterior wall, plus adding an electrical connection for the fan, which the old atmospheric unit never needed. Downsizing efficiency, though less common, has its own consideration: an old, oversized chimney originally sized for a larger or older-generation appliance may draft poorly once connected to a smaller modern atmospheric unit, sometimes requiring a liner to correctly size the flue.
A meaningful number of older Vancouver-special and character homes have a water heater sharing a chimney with a furnace or fireplace, a configuration that was common under older codes but is more tightly restricted today because of how appliances can interact on a shared flue, including one unit backfeeding exhaust into another under certain conditions. If you are replacing a water heater on a shared-flue system, expect a licensed gas fitter to evaluate whether the shared configuration is still appropriate for the replacement appliance, since orphaning one appliance on an oversized flue after removing another can itself create a draft problem.
For an atmospheric tank, a quick look at the draft hood area for soot or moisture staining, and confirming the flue pipe sections are properly seated rather than visibly gapped, are reasonable homeowner checks. For a power-vent or direct-vent unit, an occasional glance at the exterior termination for the same issues covered in vent blockage symptoms and vent corrosion signs applies just as much to water heaters as to boilers or tankless units. Anything beyond a visual check, including confirming proper draft or combustion readings, needs a licensed gas fitter with the right instruments.
Safety note
Venting and combustion work on a gas appliance is not a DIY project. If you ever smell gas, hear a hissing sound near a gas line, or notice soot, a burning odour, or headaches and drowsiness that ease when you leave the house, get everyone out immediately, do not operate switches or light anything, and call FortisBC at 1-800-663-9911 from outside the home before calling anyone else. Only a Technical Safety BC licensed gas fitter should open a vent system, adjust a flue, or work near a combustion chamber. CANRO holds gas licence LGA0043870 and boiler licence LBP0046450. Water heater venting, whether atmospheric, power-vent, or direct-vent, is part of the appliance's combustion safety system. Any replacement, especially one that changes vent type, should be evaluated and installed by a licensed gas fitter rather than assumed to be a simple swap.
No. Power-vent and direct-vent models use different vent materials and typically a different termination location than an atmospheric unit's vertical metal flue, so new venting has to be installed as part of the swap.
It was a common configuration under older building codes, especially in older Vancouver homes. Current standards look at shared flues more carefully, so any change to either appliance on that flue should include a review of whether the shared setup still drafts correctly.
Yes, the fan that pushes exhaust out needs a power connection, which is one reason a power-vent or direct-vent replacement for an atmospheric unit is a bigger job than a straightforward tank swap.
Both can operate safely when properly installed and maintained. Direct-vent units draw combustion air from outdoors rather than the room, which removes one variable, but atmospheric units have served safely for decades when their venting and combustion air supply are correctly sized and maintained.
A visual check of the flue or vent pipe for gaps, corrosion, or soot, and for sidewall terminations, a look for blockage or debris at the outside cap. A licensed technician doing annual maintenance typically checks draft and combustion readings as well.
Family-run, TSBC-licensed (gas LGA0043870 · boiler LBP0046450), serving Metro Vancouver homes since 1999. Residential, natural gas only.
Call (604) 359-1081 Email info@canroheat.ca“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.