Why does the pilot light go out when windy?

Wind can push air down certain vent types and disturb a pilot flame, and the fix usually has more to do with venting than the pilot itself.

★ 4.9/5 · 85+ reviews✅ Licensed & insured💰 Rebates & financing👨‍🔨 Since 1999

Get your free quote

Tell us what you need—we’ll call you back fast.

No obligation · We never share your info

🎉
25+ YearsServing Metro Vancouver since 1999
★
4.9 / 5 Rating85+ verified Google reviews
🛡️
Licensed & InsuredTSBC LGA0043870 · Boiler LBP0046450 · Red Seal · WorkSafeBC
💵
Rebates HandledCurrent BC programs—eligibility checked before installation

Quick answer

A pilot light can go out in windy weather mainly on appliances that use natural draft, atmospheric venting, meaning the vent relies on warm exhaust rising on its own rather than a fan pushing it out, because strong or gusting wind at the vent termination can momentarily push air back down the flue and disturb or extinguish the small pilot flame. Power-vented and direct-vent units are much less prone to this since a fan actively controls airflow, so a pilot that only goes out during windy conditions is often a sign the venting termination, its clearances, or the draft hood deserve a closer look rather than just the pilot assembly itself.

Need a licensed gas fitter for your hot water / boiler? Call CANRO at (604) 359-1081 — residential natural-gas heating and hot water across Metro Vancouver since 1999.

Why Venting Type Makes the Difference

Older-style natural draft water heaters and boilers rely on a draft hood and the natural tendency of hot exhaust gases to rise up a vertical flue. That system works well in calm conditions but is inherently sensitive to outside air pressure changes at the point where the vent terminates through the roof or wall. A strong gust hitting the termination at the wrong angle can momentarily overpower the weak natural draft and push a puff of air back down the flue, right past the pilot flame.

Power-vented and direct-vent appliances use a fan to actively move combustion air in and exhaust out, which creates a much stronger and more controlled airflow that isn't easily disrupted by outside wind. If your appliance is one of these types and the pilot is still going out in wind, that points more toward a specific vent blockage, damaged termination cap, or a failing pressure switch rather than the general natural-draft vulnerability.

Vent Termination Location and Clearances

Termination placement matters a lot for wind sensitivity. A vent that ends close to a corner where wind funnels and accelerates, near a rooftop where prevailing wind creates turbulence, or without the manufacturer's required clearance from the roofline or nearby walls, is more likely to experience the kind of gust-driven backdraft that snuffs a pilot. Metro Vancouver's exposed hillside properties on the North Shore and higher-elevation lots can see stronger and more turbulent wind at rooftop level than more sheltered locations, which is one reason some homes experience this more than others even with similar equipment.

SituationWhat it suggests
Pilot only goes out during strong wind or stormsLikely natural draft backdrafting at the vent termination
Pilot goes out in calm weather tooThermocouple, gas valve, or pilot orifice issue unrelated to wind
Only happens on power-vented unitVent blockage, damaged cap, or pressure switch fault
Started after nearby construction or roofing workVent termination clearance or path may have changed

Ruling Out a Thermocouple or Gas Valve Issue

It's worth distinguishing wind-related outages from a pilot that goes out regardless of weather, since those have different causes. A worn thermocouple, the small sensor that confirms the pilot flame is lit and keeps gas flowing to it, can fail gradually and cause the pilot to go out under any condition, wind or not. If the pilot only ever goes out during windy weather and stays lit reliably otherwise, the thermocouple is less likely to be the culprit and attention should go to the venting.

What a Technician Can Do About It

A licensed gas fitter can inspect the vent termination for damage, correct clearance, and proper cap design, some of which are specifically shaped to reduce wind-driven backdrafting. In cases where wind exposure is a persistent issue for a natural draft appliance, converting to a power-vented model at the time of replacement is often a practical long-term solution, since it removes the wind sensitivity almost entirely. They can also confirm whether the thermocouple, pilot orifice, or gas valve are within specification so wind isn't being blamed for an unrelated fault.

Safety note

If your pilot light won't relight, if you smell gas while attempting to relight it, or if it keeps going out no matter the weather, stop and call a Technical Safety BC licensed gas fitter. If you ever smell gas anywhere in the home, leave immediately and call FortisBC at 1-800-663-9911.

Frequently asked questions

Can I stop my pilot from blowing out myself?

Beyond checking that nothing is obviously blocking the vent termination from outside, this generally isn't a homeowner fix, since it involves gas venting components that should be inspected and adjusted by a licensed technician.

Is a power-vented water heater immune to wind issues?

Not entirely, but it's far less sensitive than natural draft venting because a fan actively controls airflow, so wind-related pilot outages are much less common with power-vented equipment.

Why did this only start happening recently?

New construction, roofing changes, added fencing, or even mature trees growing near the vent termination can change local wind patterns and introduce a sensitivity that wasn't there before.

Does relighting the pilot myself void anything?

Most manufacturers include homeowner relighting instructions on the appliance, but if it keeps happening repeatedly, continuing to relight it without addressing the cause isn't a long-term solution.

Could a damaged vent cap be the cause?

Yes, a damaged, missing, or incorrect vent cap can significantly increase wind sensitivity, and replacing it with the correct type is a straightforward fix for a technician.

Should I consider replacing an older natural draft unit for this reason?

If wind-related pilot outages are frequent and disruptive, switching to a power-vented model at replacement time is worth discussing, since it largely eliminates this specific problem.

Related CANRO pages

Talk to a licensed CANRO gas fitter

Family-run, TSBC-licensed (gas LGA0043870 · boiler LBP0046450), serving Metro Vancouver homes since 1999. Residential, natural gas only.

Call (604) 359-1081 Email info@canroheat.ca
Good to know

Frequently asked questions

What HVAC services does CANRO offer in Metro Vancouver?
CANRO installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses and condos throughout the Lower Mainland.
How long has CANRO been in business?
CANRO has been serving the Greater Vancouver area since 1999. Our founder George is recognised by customers as one of the most experienced boiler and hydronic heating technicians in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.
Are CANRO technicians licensed and insured?
Yes. CANRO holds Technical Safety BC contractor licences for gas (LGA0043870) and boilers (LBP0046450), our technicians are Red Seal certified for HVAC and gas, and we carry full liability insurance and WorkSafeBC coverage.
How can I book a service call?
Call (604) 359-1081, email info@canroheat.ca, or use the booking form. Provide the address, equipment and symptoms so CANRO can confirm the service scope and current appointment availability.
Do you offer free estimates?
Yes. Free in-home estimates are provided for boiler, furnace, heat pump and water-heater replacements. Diagnostic visits for repairs carry a flat service fee that is credited toward the repair if you proceed.
What brands do you service?
We service all major brands including Viessmann, Navien, IBC, Rinnai, Rheem, Bradford White, Weil-McLain, Laars, Baxi, NTI, Lennox, Carrier, Bryant, Goodman, Trane, York, Daikin, Mitsubishi Electric, AO Smith, Bosch, Noritz, Giant, GSW, John Wood, and Valor.
Do you offer government rebates for heat pumps?
A qualifying heat-pump project may be eligible under current BC programs. Check the program requirements, equipment and any required pre-approval before installation. The Canada Greener Homes Grant and Loan are closed to new applications. The program administrator determines eligibility and funding.
How quickly can you replace a broken hot water tank?
Contact CANRO with the equipment details and whether there is active leaking or no hot water. Timing depends on assessment, equipment availability, access and the required work; confirm scheduling when booking.
Why should I choose CANRO over other HVAC companies?
CANRO has been operating in Metro Vancouver since 1999 with a 4.9-star rating from 85+ Google reviews. We specialise in difficult boiler systems (Viessmann, IBC, Baxi, Laars) that many companies do not service, we give honest options instead of upselling, and our work is performed by long-term staff — not subcontractors.
Keep reading

Related water heater articles

Reviews

What Metro Vancouver homeowners say

4.9
★★★★★
85+ verified Google reviews
★★★★★

“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

Nadia Naderi
Nadia NaderiGoogle review
★★★★★

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

Arlene Colasurdo
Arlene ColasurdoGoogle review
★★★★★

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

B. Niek
B. NiekGoogle review

Need heat, hot water or cooling? Talk to a real technician today.

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.

📞 Call (604) 359-1081 Get a free quote →
📞 Call nowFree quote