An overview of the thermostat, aquastat, pressure switches, and other controls that work together to run a residential gas boiler safely and efficiently.
Tell us what you need—we’ll call you back fast.
Quick answer
A residential gas boiler's controls generally fall into three groups: operating controls that decide when and how hard the boiler fires, such as the thermostat and aquastat; safety controls that shut the boiler down if something is outside safe limits, such as pressure switches, high-limit switches, and flame sensors; and, on modern boilers, an electronic control board that coordinates all of them and often adds features like modulation and outdoor reset. Understanding roughly what each type does helps a homeowner describe symptoms accurately when calling for service.
Need a licensed gas fitter for your hot water / boiler? Call CANRO at (604) 359-1081 — residential natural-gas heating and hot water across Metro Vancouver since 1999.
The thermostat, whether it is a simple wall unit or a smart thermostat, sends the basic call for heat: the space is below the target temperature, so the system should run. The aquastat, found on boilers, reads the temperature of the water in the system and tells the boiler when to fire to maintain that water temperature, and when to stop once it is reached. On a modulating boiler, an electronic control uses sensors, sometimes including an outdoor temperature sensor, to decide not just whether to fire but how hard, adjusting the burner's output to match the actual heat loss of the building rather than always firing at full capacity.
A pressure switch confirms that combustion airflow through the vent is within the expected range before allowing the burner to fire, and shuts the boiler down if that airflow is restricted, which is the mechanism behind many of the lockouts discussed in vent blockage symptoms. A high-limit switch shuts the boiler down if water temperature climbs above a safe maximum, protecting against overheating if the aquastat or circulator were to fail. A flame sensor confirms that ignition actually occurred and a flame is present after the gas valve opens; if it does not detect a flame within the expected window, it shuts the gas valve rather than letting unburned gas accumulate. Low water cutoff controls, required on many systems, shut the boiler down if water level or pressure drops too low, since firing a boiler without adequate water can damage the heat exchanger.
| Control | What it monitors | What it does if triggered |
|---|---|---|
| Pressure switch | Combustion airflow through the vent | Prevents or stops burner firing |
| High-limit switch | Water temperature | Shuts down burner if overheating |
| Flame sensor | Presence of flame after ignition | Closes gas valve if no flame detected |
| Low water cutoff | System water level or pressure | Shuts down burner to protect heat exchanger |
| Aquastat | Water temperature target | Starts or stops burner to maintain setpoint |
On a modern boiler, an electronic control board reads all of these inputs and manages the firing sequence: pre-purge to clear the combustion chamber, ignition, flame confirmation, and modulation of the burner rate, followed by post-purge once the call for heat ends. It also manages features covered elsewhere in this series, like the anti-short-cycle timer and warm weather shutdown, and it typically displays status through a screen or a set of status lights, discussed further in boiler status lights explained. Older boilers use simpler electromechanical relays and switches to do a version of the same job with less flexibility and fewer features, but the same basic categories, operating and safety, still apply.
You do not need to diagnose which control is at fault, but being able to describe what you observed, a specific light pattern, whether the boiler seems to be trying to fire and failing versus not attempting anything at all, whether it happened right after a power outage or a cold snap, helps a technician narrow things down before they even arrive. A boiler that will not fire at all often points toward a safety control holding it back, which is the system doing its job, not something to try to bypass or reset repeatedly.
Repeatedly resetting a lockout without understanding why it tripped can mask a real problem and, in some cases, is unsafe, since lockouts exist specifically to stop the boiler from operating outside safe conditions. Adjusting an aquastat or high-limit setting without understanding the system's design can also create either a comfort problem or a safety issue. These are all reasonable jobs for a licensed gas fitter, who can access the control board's diagnostic information and confirm what actually triggered a shutdown rather than guessing.
Safety note
Boiler controls are wired directly into a gas combustion appliance, and mis-set or bypassed safety controls can affect how the burner fires and how exhaust is handled. If you ever smell gas, hear a hissing sound near a gas line, or notice soot, a burning odour, or headaches and drowsiness that ease when you leave the house, get everyone out immediately and call FortisBC at 1-800-663-9911 from outside the home before calling anyone else. Only a Technical Safety BC licensed gas fitter should adjust boiler controls, wiring, or safety switches. CANRO holds gas licence LGA0043870 and boiler licence LBP0046450. Boiler safety controls exist to stop unsafe operation, including pressure switches, high-limit switches, flame sensors, and low water cutoffs. Do not repeatedly reset a lockout or adjust a control setting yourself; have a licensed gas fitter diagnose the cause.
The thermostat tells the system whether the room needs heat. The aquastat manages the boiler's water temperature to make sure it stays within the range needed to deliver that heat safely and efficiently. They work together but control different things.
Each safety control protects against a different failure mode, such as restricted airflow, overheating, failed ignition, or low water level. Having several independent controls means a single point of failure is less likely to lead to unsafe operation.
Most boilers have a reset button, but resetting it without understanding why it tripped can mask a developing problem. If a lockout happens more than once, have a licensed gas fitter diagnose the cause rather than continuing to reset it.
The same general categories, like flame sensing and high-limit protection, exist on most gas boilers, but older units often use simpler electromechanical switches instead of an electronic control board, and may lack some features like modulation.
Describe any status lights or codes visible, whether the boiler attempts to fire at all, when the problem started, and whether it coincided with a power outage, cold snap, or recent work in the mechanical room. That context speeds up diagnosis.
Family-run, TSBC-licensed (gas LGA0043870 · boiler LBP0046450), serving Metro Vancouver homes since 1999. Residential, natural gas only.
Call (604) 359-1081 Email info@canroheat.ca“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.