A discharging relief valve on a Tsawwassen boiler is releasing excess system pressure, usually from a waterlogged expansion tank, and needs prompt diagnosis rather than being capped.
Tell us what you need—we’ll call you back fast.
Quick answer
When a boiler's relief valve discharges water, it's releasing pressure that's built up beyond a safe threshold, most commonly because the expansion tank has lost its air charge and can't absorb normal thermal expansion, or because the system has been overfilled. The valve itself must never be capped or plugged — it needs a licensed technician to find and fix the source of the excess pressure.
Need a licensed gas fitter for your gas boiler? Call CANRO at (604) 359-1081 — residential natural-gas heating and hot water across Metro Vancouver since 1999.
The relief valve is a safety device that opens automatically once pressure inside the boiler and its piping climbs past a safe limit, releasing water to bring it back down before a fitting fails or the heat exchanger is damaged. A discharging valve is the system telling you something upstream is pushing pressure too high — it's the symptom, not the underlying fault.
An occasional small weep is not unusual, but a valve that discharges repeatedly or won't stop means the actual cause needs attention rather than being left alone.
A number of Tsawwassen's older homes are still running the original hydronic system components from decades ago, including expansion tanks well past their typical service life. On these systems, a waterlogged expansion tank is often the very first sign that other original components may also be due for attention.
If your home has had recent plumbing work, it's worth checking whether a new backflow preventer or pressure-reducing valve was installed on the incoming water line, since these devices can inadvertently turn what used to be a semi-open system into a fully closed one, changing how much expansion capacity is actually needed and sometimes triggering relief valve discharge on a system that had never had the issue before.
A technician checks the expansion tank's air pre-charge with a gauge at its top valve once the system is depressurized, tests the fill valve for proper shutoff, and confirms the relief valve is rated correctly for the system before concluding the valve itself has failed. A waterlogged or undersized expansion tank gets replaced; a stuck fill valve is replaced in its place.
Replacing the expansion tank or fill valve resolves the great majority of these cases and is a routine, moderate-cost repair. A worn relief valve is inexpensive to replace on its own. Boiler replacement isn't usually indicated by this symptom unless the boiler is already old enough that a larger repair doesn't make sense on its own.
As water heats, it expands slightly, and a fully closed hydronic system needs somewhere for that expansion to go without raising pressure dangerously. An expansion tank handles this with an internal rubber diaphragm separating a small charge of air from the system water; when the water expands, it compresses that air cushion rather than pushing pressure straight up. Over years, that air charge slowly diffuses out or leaks from the tank's valve, and once it's gone the tank is effectively just full of water and can no longer cushion anything, sending pressure directly to the relief valve instead.
This is why checking the tank's air pre-charge with a gauge comes before replacing the relief valve — swapping just the valve without addressing a waterlogged tank usually means the new valve starts discharging again within a matter of weeks.
Most residential boilers run a cold fill pressure around 12 to 15 psi, though the exact figure depends on system design and how much piping sits above the boiler. Pressure climbs somewhat as the system heats up, and the relief valve is set to open well above that range, typically around 30 psi, specifically so ordinary operation never triggers it.
Knowing what your system's normal cold and hot pressure readings look like makes it easier to catch a developing problem before the relief valve ever opens, and it's a simple thing a technician can point out during a routine service visit on your Tsawwassen home.
An expansion tank's typical service life runs to years rather than decades, so a system that's original to a home built or last renovated a long time ago is statistically more likely to have a tank nearing the end of its useful life than one that's had recent service.
If you've noticed the discharge specifically after the boiler has been running for a while rather than right when it starts, that timing is consistent with thermal expansion building pressure gradually as the system heats, which is exactly the pattern a healthy expansion tank is supposed to absorb before it ever reaches the relief valve.
Safety note
A boiler is a pressure vessel connected to a gas burner, so any work on the relief valve, expansion tank, or gas train should go to a Technical Safety BC licensed gas fitter. If the relief valve is discharging hot water or you smell gas at any point, leave the area and call FortisBC at 1-800-663-9911 from outside the home.
The valve releasing pressure is it working correctly, but it signals an underlying pressure issue that should be diagnosed promptly rather than left alone.
No, never cap or plug a relief valve — doing so removes a critical safety protection and can allow dangerous pressure to build with nowhere to escape.
A waterlogged expansion tank that has lost its air charge is the most common cause, since it can no longer cushion the normal pressure rise as the system heats.
A tank that feels heavy or sounds solid rather than hollow when tapped is a sign it may be waterlogged, though a technician confirms this with a direct gauge check.
It's not the same urgency as a gas smell, but a relief valve discharging repeatedly or continuously should be looked at promptly since it points to an ongoing pressure problem.
Homes still running original hydronic components from decades ago often have an expansion tank well past its typical service life, which is a common first sign of aging system components.
Family-run, TSBC-licensed (gas LGA0043870 · boiler LBP0046450), serving Metro Vancouver homes since 1999. Residential, natural gas only.
Call (604) 359-1081 Email info@canroheat.ca“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.