York Error Code Guide · Greater Vancouver

York error codes explained — and what to do

Every common York fault code with what it means, the likely cause, and how CANRO Heating & Cooling fixes it — servicing York furnaces, air conditioners and heat pumps across Greater Vancouver since 1999. Licensed Technical Safety BC contractor (gas LGA0043870 · boiler LBP0046450).

York furnaces use a status LED that flashes a blink count on the control board; Affinity communicating systems show codes on the thermostat. York, Luxaire and Coleman share these controls.

Important: One power-cycle reset is generally safe for a transient fault. If the same code returns within minutes, stop resetting — lockouts exist to protect the heat exchanger, ignition system and gas-valve safety circuit. Note the exact code and call CANRO at (604) 359-1081. We carry common York parts on every truck, so most code-triggered faults are fixed in one visit. Smell gas? Leave and call the gas utility emergency line first.

Quick reference — tap a code to jump

1 Flash2 Flashes3 Flashes4 Flashes5 Flashes6 Flashes7 Flashes8 FlashesCool/HP

York error codes — detailed guide

York code

1 Flash — Normal — Call for Heat

✓ Not an immediate emergency — book promptly

What it means: Control operating normally.

Common causes: Normal.

What to do: None.

Reset guidance: n/a

York code

2 Flashes — External Lockout

✓ Not an immediate emergency — book promptly

What it means: Retries/recycles exceeded — failed ignition or repeated flame loss.

Common causes: Flame sensor, igniter, gas pressure, gas valve, condensate.

What to do: One power cycle OK; recurring needs service.

Reset guidance: one cycle OK

York code

3 Flashes — Pressure Switch Open / Stuck

✓ Not an immediate emergency — book promptly

What it means: Draft/pressure switch did not prove or shorted.

Common causes: Blocked vent/intake, condensate trap, inducer, switch/tubing.

What to do: Inspect vent if safe; otherwise call.

Reset guidance: no

York code

4 Flashes — Open High Limit

⚠ Possible emergency in winter

What it means: High-limit/rollout open from overheating.

Common causes: Low airflow (filter), blocked flue, rollout (possible cracked HX).

What to do: Replace filter; if it returns, call.

Reset guidance: no

York code

5 Flashes — Flame Sensed With No Call

🚨 EMERGENCY — call right away

What it means: Flame present with valve off.

Common causes: Gas-valve leak-by, sensor/grounding.

What to do: Shut off and call.

Reset guidance: no

York code

6 Flashes — Low / Weak Flame

✓ Not an immediate emergency — book promptly

What it means: Flame current low.

Common causes: Fouled flame sensor.

What to do: Clean/replace sensor.

Reset guidance: one cycle OK

York code

7 Flashes — Low Flame Current / Gas Valve

✓ Not an immediate emergency — book promptly

What it means: Weak sensing or gas-valve circuit.

Common causes: Sensor, wiring, valve.

What to do: Service.

Reset guidance: one cycle OK

York code

8 Flashes — Ignition Lockout

✓ Not an immediate emergency — book promptly

What it means: Hard lockout after failed ignition.

Common causes: Igniter, gas supply, valve, sensor.

What to do: Call — note the code.

Reset guidance: one cycle OK

York code

Cool/HP — A/C or Heat-Pump Fault

✓ Not an immediate emergency — book promptly

What it means: Outdoor unit fault — Affinity communicating units show a code.

Common causes: Capacitor, contactor, refrigerant, defrost, reversing valve, compressor.

What to do: Read code and call.

Reset guidance: no

York showing a code and no heat or cooling?

CANRO offers same-day and after-hours emergency repair across Greater Vancouver — no-heat, no-cooling and no-hot-water calls are prioritized. Note your code and call now.

📞 Call (604) 359-1081 — emergency York repair

CANRO York service across Greater Vancouver

Our licensed Red Seal technicians diagnose and repair York furnaces, air conditioners and heat pumps in every Metro Vancouver city — Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North & West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows and Maple Ridge — with honest, up-front pricing and a 4.9-star rating from 85+ Google reviews.

This York error-code guide is maintained by the CANRO Heating & Cooling team from 25+ years of HVAC install, service and repair across Greater Vancouver. Flash-count and code behaviour described match current York model manuals; exact codes can vary by model and series, so confirm against your unit’s manual or tell us the code when you call. Last reviewed June 2026.

Frequently asked questions

What does my York error code mean?

Each York code points to a specific fault — ignition, pressure/draft, high-limit, flame-sensing, blower or communication. The guide above lists each one with its cause and fix. Tell us the exact code when you call (604) 359-1081 and we usually know the likely cause before arriving.

Is it safe to reset my York system?

One power-cycle reset is fine for a one-off fault. If the same code returns within minutes, stop — repeated resets stress the ignition, gas-valve and heat-exchanger safety circuits. Note the code and call.

Can you repair my York system the same day?

Yes — CANRO offers same-day and after-hours emergency response across Greater Vancouver, and we carry common York parts so most code faults are fixed in one visit. Call (604) 359-1081.

Is CANRO licensed to work on York equipment?

Yes — Technical Safety BC gas contractor LGA0043870 and boiler licence LBP0046450, Red Seal technicians, fully insured, serving Greater Vancouver since 1999.

Good to know

Frequently asked questions

What HVAC services does CANRO offer in Metro Vancouver?
CANRO installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses and condos throughout the Lower Mainland.
How long has CANRO been in business?
CANRO has been serving the Greater Vancouver area since 1999. Our founder George is recognised by customers as one of the most experienced boiler and hydronic heating technicians in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.
Are CANRO technicians licensed and insured?
Yes. CANRO holds Technical Safety BC contractor licences for gas (LGA0043870) and boilers (LBP0046450), our technicians are Red Seal certified for HVAC and gas, and we carry full liability insurance and WorkSafeBC coverage.
How can I book a service call?
Call (604) 359-1081, email info@canroheat.ca, or use the booking form. Provide the address, equipment and symptoms so CANRO can confirm the service scope and current appointment availability.
Do you offer free estimates?
Yes. Free in-home estimates are provided for boiler, furnace, heat pump and water-heater replacements. Diagnostic visits for repairs carry a flat service fee that is credited toward the repair if you proceed.
What brands do you service?
We service all major brands including Viessmann, Navien, IBC, Rinnai, Rheem, Bradford White, Weil-McLain, Laars, Baxi, NTI, Lennox, Carrier, Bryant, Goodman, Trane, York, Daikin, Mitsubishi Electric, AO Smith, Bosch, Noritz, Giant, GSW, John Wood, and Valor.
Do you offer government rebates for heat pumps?
A qualifying heat-pump project may be eligible under current BC programs. Check the program requirements, equipment and any required pre-approval before installation. The Canada Greener Homes Grant and Loan are closed to new applications. The program administrator determines eligibility and funding.
How quickly can you replace a broken hot water tank?
Contact CANRO with the equipment details and whether there is active leaking or no hot water. Timing depends on assessment, equipment availability, access and the required work; confirm scheduling when booking.
Why should I choose CANRO over other HVAC companies?
CANRO has been operating in Metro Vancouver since 1999 with a 4.9-star rating from 85+ Google reviews. We specialise in difficult boiler systems (Viessmann, IBC, Baxi, Laars) that many companies do not service, we give honest options instead of upselling, and our work is performed by long-term staff — not subcontractors.
Keep reading

Related hvac error codes articles

Reviews

What Metro Vancouver homeowners say

4.9
★★★★★
85+ verified Google reviews
★★★★★

“Canro does an amazing job! Super professional and skilled with everything—boilers, furnaces, and AC. Always a pleasure working with them!”

Nadia Naderi
Nadia NaderiGoogle review
★★★★★

“Five stars for Canro. We needed a replacement of a 30-year-old boiler. A new high-efficiency unit was installed—clean, professional work.”

Arlene Colasurdo
Arlene ColasurdoGoogle review
★★★★★

“I can’t speak highly enough about George, who was recommended for a boiler service call for my parents’ home. George is excellent.”

B. Niek
B. NiekGoogle review

Need heat, hot water or cooling? Talk to a real technician today.

25+ years keeping Metro Vancouver homes comfortable. Honest advice, upfront pricing, work that lasts.

📞 Call (604) 359-1081 Get a free quote →
📞 Call nowFree quote